Palabras contadas: diagnostics: 5, langmuir: 9, probe: 32
Prevosto, L. - Kelly, H. - Mancinelli, B.R.
J Appl Phys 2012;112(6)
2012

Descripción: Langmuir probe measurements in an atmospheric pressure direct current (dc) plasma jet are reported. Sweeping probes were used. The experiment was carried out using a dc non-transferred arc torch with a rod-type cathode and an anode of 5 mm diameter. The torch was operated at a nominal power level of 15 kW with a nitrogen flow rate of 25 Nl min -1. A flat ion saturation region was found in the current-voltage curve of the probe. The ion saturation current to a cylindrical probe in a high-pressure non local thermal equilibrium (LTE) plasma was modeled. Thermal effects and ionization/recombination processes inside the probe perturbed region were taken into account. Averaged radial profiles of the electron and heavy particle temperatures as well as the electron density were obtained. An electron temperature around 11 000 K, a heavy particle temperature around 9500 K and an electron density of about 4 × 10 22 m -3, were found at the jet centre at 3.5 mm downstream from the torch exit. Large deviations from kinetic equilibrium were found throughout the plasma jet. The electron and heavy particle temperature profiles showed good agreement with those reported in the literature by using spectroscopic techniques. It was also found that the temperature radial profile based on LTE was very close to that of the electrons. The calculations have shown that this method is particularly useful for studying spraying-type plasma jets characterized by electron temperatures in the range 9000-14 000 K. © 2012 American Institute of Physics.
...ver más

Tipo de documento: info:ar-repo/semantics/artículo

Prevosto, L. - Kelly, H. - Mancinelli, B.
J Appl Phys 2011;110(8)
2011

Descripción: Experimental observations on the plasma dynamics inside the nozzle of a 30 A oxygen cutting torch operated at conditions close to the double arcing are reported. It is employed a technique previously developed in our laboratory consisting in using the nozzle as a large-sized Langmuir probe. Based on the behavior of the ion current signal and simple estimations, it is concluded that (1) the non-equilibrium plasma inside the nozzle is far from the steady state in time, in contrast to what is frequently assumed. The power supply ripple was identified as the main fluctuations source and (2) large-scale plasma fluctuations inside the nozzle could cause transient (total duration of the order of 100 μs) Townsend avalanches developing in the space-charge layer located between the arc plasma and the nozzle wall. Such events trigger the so called non-destructive double-arcing phenomena without appealing to the presence of insulating films deposited inside the nozzle orifice, as was previously proposed in the literature. © 2011 American Institute of Physics.
...ver más

Tipo de documento: info:ar-repo/semantics/artículo